National service hotline:008615094320000

Environmental Equipment

Years of experience
solutions across various industries

National service hotline
008615094320000

Electrolytic chlorine dioxide generator E

结构和工作原理

The KW series of high-efficiency mixed disinfectant generators are carefully designed after repeated research and testing on electrode materials, anode and cathode spacing, electrolysis area, diaphragm materials, etc. based on various original disinfectant generators. What is produced by electrolysis is mainly C102, mixed with C12, O3, H202, and other strong oxidants. It has strong oxidizing and sterilizing capabilities and can kill various spore viruses in the water. Test comparison proves: C102 is more effective, with an average killing rate of 100% within five minutes. At the same time, it can oxidize organic matter and phenol, Fe2+, Mn2+, CN- and other substances in the water without producing chloroform (carcinogen), chlorophenol, etc. Tests by the Chinese Academy of Preventive Medicine have proven that its bactericidal ability is higher than that of current disinfectants, especially for drinking water disinfection, and its toxicology is safe and reliable. Therefore, it has extensive use value and has reached the advanced level at home and abroad in the 1990s.

Equipment composition and working principle

1、Equipment composition:

KW series high-efficiency mixed disinfectant generator consists of electrolytic tank, DC power supply, salt dissolving tank and supporting pipelines, valves, instruments, etc.

2、Working principle:

Add a certain concentration or saturated salt solution to the anode chamber of the electrolytic cell, and add clean water to the cathode chamber of the electrolytic cell at the same time. Turn on the 12V DC power supply to start electrolysis. Mixed disinfectants such as C102, C12, 03, H202, etc. can be produced through the water ejector. Press the tube feet to allow the gas to be inhaled into the water for disinfection. Features

1、Strong integrity, small size, light weight and beautiful appearance.

2、The service life of the anode is as long as 5 to 7 years.

3、The power supply performance is reliable and adopts thyristor DC power supply.

4、Strong corrosion resistance, the electrolytic cell is made of high-quality steel and polyvinyl chloride plastic.

5、The diaphragm has high conductivity and is easy to replace.

6、The electrolytic tank has automatic temperature control and cooling, and the operation is stable and continuous.

7、All pipes and valves are made of ABS engineering plastic.

·Application scope

1、Disinfection of various water plants.

2、Secondary water supply and drinking water disinfection for high-rise buildings.

3、Disinfect drinking water for rural areas, towns, mines, troops and field workers, and water supply stations along railway lines.

4、Sterilization and disinfection of swimming pool and bath water.

5、Algae removal and sterilization of cooling circulating water for industrial use in power plants, boilers and other industries.

6、Sterilization and odor removal during reclaimed water reuse.

7、Disinfection treatment of various sewage treatment.

8、Sterilization and disinfection of restaurants, hotels and tableware.

9、Sterilization and disinfection of utensils in food and beverage factories.

10、Sterilization and other disinfection of pipeline environment in dairy plants and slaughterhouses.

11、Sterilization and disinfection of hospital sewage and instruments.

12、Cyanide-breaking treatment of electroplating cyanide-containing wastewater.

13、Decolorization treatment of printing and dyeing wastewater.

14、Dephenolization treatment of phenol-containing wastewater.

15、Elimination of sulfate-reducing bacteria in petroleum pipelines.

model

Occurrence

salt consumption

(g/g)

Power supply

YD

power pressure

V

electrolysis current

A

Overall dimensions (mm)

Length (L)

Width(W)

High(H)

KWII-1

50

1.6

0.6

220

≤50

800

650

1300

KWII-2

100

1.6

1.2

220

≤100

800

650

1300

KWII-3

200

1.6

2.5

380

≤200

800

650

1300

KWII-4

300

1.6

3.5

380

≤400

1000

800

1300

KWII-5

300

1.6

4.5

380

≤500

1000

800

1300

KWII-6

500

1.6

5.5

380

≤600

1000

800

1300

KWII-7

600

1.6

6.8

380

≤400

1000

800

1300

KWII-8

800

1.6

9.5

380

≤500

1000

800

1450

KWII-9

1000

1.6

12.0

380

≤500

1000

800

1450

KWII-10

2000

1.6

24.0

380

≤500

1000

1200

1450

Electric cabinet dimensions:

100A~200A 600×450×1200

400A~800A 750×500×1400

1000A 750×500×1450

2000A 850×650×1450

Note: 1. The distance between the KWII-5 type electrical cabinet and the equipment body is 300mm.

2. Models larger than KWII-11 can be designed and manufactured separately.

  • Engineering design
  • Engineering general contracting
  • Water operations
  • Environmental protection equipment

CopyRight © Jiangsu ZEYU Environmental Engineering Co., Ltd.       Su ICP No. 14007113-1

National service hotline
008615094320000

online service

One-on-one professional services
top